| Sign In | Join Free | My futurenowinc.com | 
              
  | 
      
Place of Origin : China
Brand Name : Kingsine
Certification : ISO9001,CE
Model Number : KS908
MOQ : 1 set
Delivery Time : 15 working days
Payment Terms : T/T in advance ,L/C
Supply Ability : 50 sets/ month
Modbus RTU - Test
Built-in high precision AC/DC/Harmonic standard source output
Voltage Output Shift:100V/220/380V Auto switch
Current Output Shift:1A/5A/10A Auto switch
 
Technical Data of KS908
| 
			 Voltage (AC) Output/Measure  | 
		|
| 
			 Shift  | 
			
			 100V/220/380V Auto switch  | 
		
| 
			 Adjusting range  | 
			
			 0 ... 120%  | 
		
| 
			 Min Adjusting Unit  | 
			
			 Shift x 0.01%  | 
		
| 
			 Resolution  | 
			
			 Shift x 0.01%  | 
		
| 
			 Accuracy  | 
			
			 0.05%RG (RG abbr. range)  | 
		
| 
			 Stability  | 
			
			 0.01%/1min  | 
		
| 
			 Current (AC) Output/Measure  | 
		|
| 
			 Shift  | 
			
			 1A/5A/10AAuto switch  | 
		
| 
			 Adjusting range  | 
			
			 0 ... 120%  | 
		
| 
			 Min Adjusting Unit  | 
			
			 Shift x 0.01%  | 
		
| 
			 Resolution  | 
			
			 Shift x 0.01%  | 
		
| 
			 Accuracy  | 
			
			 0.05%RG  | 
		
| 
			 Stability  | 
			
			 0.01%/1min  | 
		
| 
			 Power Output/Measure  | 
		|
| 
			 Min Adjusting Unit  | 
			
			 Shift x 0.01%  | 
		
| 
			 Resolution  | 
			
			 Shift x 0.01%  | 
		
| 
			 Accuracy  | 
			
			 0.05%RG (F>0.5)  | 
		
| 
			 Stability  | 
			
			 0.01%/1min  | 
		
| 
			 Frequency Output/Measure  | 
		|
| 
			 Range  | 
			
			 45.000...65.000Hz  | 
		
| 
			 Min Adjusting Unit  | 
			
			 0.001Hz  | 
		
| 
			 Accuracy  | 
			
			 0.01%RD  | 
		
| 
			 Phase Output/Measure  | 
		|
| 
			 Range  | 
			
			 0.00° ... 359.99°  | 
		
| 
			 Min Adjusting Unit  | 
			
			 0.01°  | 
		
| 
			 Resolution  | 
			
			 0.01°  | 
		
| 
			 Accuracy  | 
			
			 0.05°  | 
		
| 
			 Power factor Output/Measure  | 
		|
| 
			 Output range  | 
			
			 -1 ... 0 ... +1  | 
		
| 
			 Min Adjusting Unit  | 
			
			 0.0001  | 
		
| 
			 Accuracy  | 
			
			 0.0005  | 
		
| 
			 Harmonic Output/Measure  | 
		|
| 
			 Set range  | 
			
			 2 ... 31 times  | 
		
| 
			 Content  | 
			
			 Voltage, Current≤30%( compared with Fundamental Wave)  | 
		
| 
			 Harmonic output accuracy  | 
			
			 0.1%(2 ... 19 times, compared with Fundamental Wave)  | 
		
| 
			 Resolution  | 
			
			 0.2%(20 ... 31 times, compared with Fundamental Wave)  | 
		
| 
			 Harmonic Phase  | 
			
			 0.00° ... 359.99°  | 
		
| 
			 Output Voltage and Current distortion  | 
		|
| 
			 <0.2%(non capacitance load)  | 
		|
| 
			 Max AC Output Load  | 
		|
| 
			 Voltage 25VA, Current 25VA  | 
		|
| 
			 Voltage (DC) Output/Measure  | 
		|
| 
			 Shift  | 
			
			 100mV/1V/10V/30V/100V/300V  | 
		
| 
			 Adjusting range  | 
			
			 0 ... 120%, 0 ... 110% at shift 750V  | 
		
| 
			 Min Adjusting Unit  | 
			
			 Shift x 0.01%  | 
		
| 
			 Resolution  | 
			
			 Shift x 0.01%  | 
		
| 
			 Accuracy  | 
			
			 0.05%RG  | 
		
| 
			 Stability  | 
			
			 0.01%/1min  | 
		
| 
			 Current (DC) Output/Measure  | 
		|
| 
			 Shift  | 
			
			 1mA/10mA/20mA  | 
		
| 
			 Adjusting range  | 
			
			 0 ... 120%  | 
		
| 
			 Min Adjusting Unit  | 
			
			 Shift x 0.01%  | 
		
| 
			 Resolution  | 
			
			 Shift x 0.01%  | 
		
| 
			 Accuracy  | 
			
			 0.05%RG  | 
		
| 
			 Stability  | 
			
			 0.01%/1min  | 
		
| 
			 Max DC Output Load  | 
		|
| 
			 Voltage 20VA, Current 25VA  | 
		|
| 
			 DC measure  | 
		|
| 
			 Voltage measure range  | 
			
			 ±10V  | 
		
| 
			 Current measure range  | 
			
			 ±20mA  | 
		
| 
			 Accuracy  | 
			
			 0.01%RG  | 
		
| 
			 Index measure reference condition  | 
		|
| 
			 Work temperature  | 
			
			 0°C ... 40°C  | 
		
| 
			 Humidity range  | 
			
			 ≤85 %  | 
		
| 
			 Work power supply range  | 
			
			 220VAC±15%, 50Hz  | 
		
| 
			 Weight  | 
			
			 18KG  | 
		
| 
			 Dimensions  | 
			
			 450(D)×180 (W)×380 (H) mm  | 
		
| 
			 Interface  | 
			
			 RJ45, USB, PS/2, RS232  | 
		
Major functions:
| KS901 | KS907 | KS908 | |
| AC Standard Sources | ● | ● | ● | 
| DC Standard Sources | ● | ● | ● | 
| Power Standard Sources | ● | ● | ● | 
| Harmonic Standard Sources | ● | ● | ● | 
| Indicator Test | ● | ○ | ● | 
| Transmitter Test | ● | ● | ● | 
| Energy Meter Test | ● | ● | ● | 
| Rtu Test | ● | ● | ● | 
| Standard Meter | ○ | ○ | ● | 
| Sychronization test | ● | ● | |
| Tele-control, tele-communication | ● | ● | 
Note: ● :With the corresponding function modules
○ : Without the corresponding function modules
● Built-in high precision AC/DC/Harmonic standard source output;
● User-friendly interface comes by the use of Windows CE operating system kernel;
● Functions available such as calibration of AC sampling, transducer, and energy meter; auto-compute on the calibration error and follow-up report creating; report template can be defined by the users;
● Mouse and keyboard built in panel or external connection available;
● USB port convenient for data transmissio;
● Can be used as a standard meter to monitor the information of electric quantity of AC transmission line (available in KS905, KS906);
● Workable without PC, and provides RS232 and RJ45 to support PC communications. And the communication protocol is open to the users to make auto testing solution if necessary;
● Can be run offline, while providing network RJ45 port and RS232 port and PC communication, communication protocol and opening up to the user anduser-friendly program to test automatically;
● Compact size and portable carrying, convenient for on-site operation
| 
                                             | 
                
                        KS908 Modbus RTU - Test Images |